
{"id":42846,"date":"2024-09-24T15:06:54","date_gmt":"2024-09-24T14:06:54","guid":{"rendered":"https:\/\/www.btitrainingcenter.com\/assessing-the-impact-of-ios-scanning-accuracy-on-additively-manufactured-occlusal-splints\/"},"modified":"2025-08-01T15:28:09","modified_gmt":"2025-08-01T14:28:09","slug":"assessing-the-impact-of-ios-scanning-accuracy-on-additively-manufactured-occlusal-splints","status":"publish","type":"post","link":"https:\/\/www.btitrainingcenter.com\/en\/assessing-the-impact-of-ios-scanning-accuracy-on-additively-manufactured-occlusal-splints\/","title":{"rendered":"Assessing the Impact of IOS Scanning Accuracy on Additively Manufactured Occlusal Splints"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row content_text_aligment=&#8221;left&#8221; row_background_lines=&#8221;no&#8221;][vc_column][vc_column_text css=&#8221;&#8221;]<\/p>\n<h3 class=\"title\">Abstract<\/h3>\n<div id=\"enc-abstract\" class=\"abstract-content selected\">\n<div id=\"enc-abstract\" class=\"abstract-content selected\">\n<p><strong class=\"sub-title\">Introduction: <\/strong>Digital workflow and intraoral scanners (IOSs) are used to clinically obtain data for a wide range of applications in restorative dentistry. The study aimed to compare two different IOSs with inexperienced users in the digital workflow of oral split manufacturing.<\/p>\n<p><strong class=\"sub-title\">Material and Methods:\u00a0<\/strong>Anonymous stone models of upper and lower dentate patients were used. Both models were scanned with a desktop 3D scanner 3Shape D2000 to obtain the reference models (STLR). Ten inexperienced operators scanned each model three times with each IOS system (3Shape TRIOS 3 and Carestream CS 3800). Finally, 20 intraoral scanners were randomly chosen from the obtained dataset (10 per IOS system) to design and manufacture 20 nightguards. All the nightguards were scanned. Trueness and precision were calculated and compared between the two IOS systems.<\/p>\n<p><strong class=\"sub-title\">Results:\u00a0<\/strong>All the mean errors both for trueness and precision were below 40 \u00b5m, more than acceptable for the design and manufacturing of intraoral devices such as nightguards. All the mean errors (except one) for trueness between the inner part of the nightguards and the upper control model were below 100 \u00b5m, less than a printed layer height. For inexperienced operators, both IOSs are suitable for a digital workflow of manufacturing occlusal splints.<\/div>\n<p><strong class=\"sub-title\">Keywords:\u00a0<\/strong>accuracy; digital dentistry; intraoral scanner; nightguard; precision; trueness.<\/div>\n<p>[\/vc_column_text][vc_empty_space][vc_column_text]<\/p>\n<h3>Figures<\/h3>\n<p>[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row][vc_row content_placement=&#8221;middle&#8221; content_text_aligment=&#8221;center&#8221;][vc_column]<div class=\"qodef-image-gallery qodef-grid-list qodef-disable-bottom-space  qodef-ig-grid-type qodef-four-columns qodef-tiny-space  qodef-image-behavior-lightbox\">\n\t<div class=\"qodef-ig-inner qodef-outer-space\">\n\t\t\t\t\t<div class=\"qodef-ig-image qodef-item-space\">\n\t\t\t\t<div class=\"qodef-ig-image-inner\">\n\t\t\t\t\t\t\t\t\t\t\t<a itemprop=\"image\" class=\"qodef-ig-lightbox\" href=\"https:\/\/www.btitrainingcenter.com\/wp-content\/uploads\/2021\/08\/dentistry-12-00298-g0A1.jpg\" data-rel=\"prettyPhoto[image_gallery_pretty_photo-200]\" title=\"&lt;strong&gt;Figure A1.&lt;\/strong&gt; Mesh-to-mesh point-based registration, ICP algorithm, and colour-coded surface mapping of the manufactured splints and the STLR model.\">\n\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.btitrainingcenter.com\/wp-content\/uploads\/2021\/08\/dentistry-12-00298-g0A1-200x200.jpg\" alt=\"\" width=\"200\" height=\"200\" \/>\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\t<div class=\"qodef-ig-image qodef-item-space\">\n\t\t\t\t<div class=\"qodef-ig-image-inner\">\n\t\t\t\t\t\t\t\t\t\t\t<a itemprop=\"image\" class=\"qodef-ig-lightbox\" href=\"https:\/\/www.btitrainingcenter.com\/wp-content\/uploads\/2021\/08\/dentistry-12-00298-g001.jpg\" data-rel=\"prettyPhoto[image_gallery_pretty_photo-200]\" title=\"&lt;strong&gt;Figure 1.&lt;\/strong&gt; Schematic representation of the study design.\">\n\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.btitrainingcenter.com\/wp-content\/uploads\/2021\/08\/dentistry-12-00298-g001-200x200.jpg\" alt=\"\" width=\"200\" height=\"200\" \/>\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\t<div class=\"qodef-ig-image qodef-item-space\">\n\t\t\t\t<div class=\"qodef-ig-image-inner\">\n\t\t\t\t\t\t\t\t\t\t\t<a itemprop=\"image\" class=\"qodef-ig-lightbox\" href=\"https:\/\/www.btitrainingcenter.com\/wp-content\/uploads\/2021\/08\/dentistry-12-00298-g002.jpg\" data-rel=\"prettyPhoto[image_gallery_pretty_photo-200]\" title=\"&lt;strong&gt;Figure 2.&lt;\/strong&gt; (a) Scanning protocol for the maxillary complete-arch digital scans performed followed 3Shape recommendation; (b) scanning protocol for the maxillary right quadrant digital scans performed followed Carestream recommendations.\">\n\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.btitrainingcenter.com\/wp-content\/uploads\/2021\/08\/dentistry-12-00298-g002-200x200.jpg\" alt=\"\" width=\"200\" height=\"200\" \/>\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\t<div class=\"qodef-ig-image qodef-item-space\">\n\t\t\t\t<div class=\"qodef-ig-image-inner\">\n\t\t\t\t\t\t\t\t\t\t\t<a itemprop=\"image\" class=\"qodef-ig-lightbox\" href=\"https:\/\/www.btitrainingcenter.com\/wp-content\/uploads\/2021\/08\/dentistry-12-00298-g003.jpg\" data-rel=\"prettyPhoto[image_gallery_pretty_photo-200]\" title=\"&lt;strong&gt;Figure 3.&lt;\/strong&gt; Selected ROI (in green) defined by a spline in Geomagic Studio 12.\">\n\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.btitrainingcenter.com\/wp-content\/uploads\/2021\/08\/dentistry-12-00298-g003-200x200.jpg\" alt=\"\" width=\"200\" height=\"200\" \/>\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t\t\t<div class=\"qodef-ig-image qodef-item-space\">\n\t\t\t\t<div class=\"qodef-ig-image-inner\">\n\t\t\t\t\t\t\t\t\t\t\t<a itemprop=\"image\" class=\"qodef-ig-lightbox\" href=\"https:\/\/www.btitrainingcenter.com\/wp-content\/uploads\/2021\/08\/dentistry-12-00298-g004.jpg\" data-rel=\"prettyPhoto[image_gallery_pretty_photo-200]\" title=\"&lt;strong&gt;Figure 4.&lt;\/strong&gt; Mesh-to-mesh point-based registration, ICP algorithm, and colour-coded surface mapping.\">\n\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.btitrainingcenter.com\/wp-content\/uploads\/2021\/08\/dentistry-12-00298-g004-200x200.jpg\" alt=\"\" width=\"200\" height=\"200\" \/>\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>\n<\/div>[vc_empty_space height=&#8221;50px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column]<a itemprop=\"url\" href=\"https:\/\/www.btitrainingcenter.com\/wp-content\/uploads\/2021\/08\/18-dentistry-12-00298.pdf\" target=\"_blank\"  class=\"qodef-btn qodef-btn-medium qodef-btn-solid btnWebRosa2\"  >\n    <span class=\"qodef-btn-text\">Download article<\/span>\n    <\/a>[\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p><strong>Dent J (Basel). 2024 Sep 24;12(10):298. <\/strong><br \/>\n Digital workflow and intraoral scanners (IOSs) are used to clinically obtain data for a wide range of applications in restorative dentistry. The study aimed to compare two different IOSs with inexperienced users in the digital workflow of oral split manufacturing.<\/p>\n","protected":false},"author":2002,"featured_media":42807,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[149],"tags":[],"class_list":["post-42846","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-oral-implantology"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.btitrainingcenter.com\/en\/wp-json\/wp\/v2\/posts\/42846","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.btitrainingcenter.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.btitrainingcenter.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.btitrainingcenter.com\/en\/wp-json\/wp\/v2\/users\/2002"}],"replies":[{"embeddable":true,"href":"https:\/\/www.btitrainingcenter.com\/en\/wp-json\/wp\/v2\/comments?post=42846"}],"version-history":[{"count":1,"href":"https:\/\/www.btitrainingcenter.com\/en\/wp-json\/wp\/v2\/posts\/42846\/revisions"}],"predecessor-version":[{"id":42847,"href":"https:\/\/www.btitrainingcenter.com\/en\/wp-json\/wp\/v2\/posts\/42846\/revisions\/42847"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.btitrainingcenter.com\/en\/wp-json\/wp\/v2\/media\/42807"}],"wp:attachment":[{"href":"https:\/\/www.btitrainingcenter.com\/en\/wp-json\/wp\/v2\/media?parent=42846"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.btitrainingcenter.com\/en\/wp-json\/wp\/v2\/categories?post=42846"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.btitrainingcenter.com\/en\/wp-json\/wp\/v2\/tags?post=42846"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}