
{"id":33759,"date":"2024-02-05T17:39:54","date_gmt":"2024-02-05T16:39:54","guid":{"rendered":"https:\/\/www.btitrainingcenter.com\/clinical-performance-of-additively-manufactured-subperiosteal-implants-a-systematic-review\/"},"modified":"2025-10-09T12:27:13","modified_gmt":"2025-10-09T11:27:13","slug":"clinical-performance-of-additively-manufactured-subperiosteal-implants-a-systematic-review","status":"publish","type":"post","link":"https:\/\/www.btitrainingcenter.com\/de\/clinical-performance-of-additively-manufactured-subperiosteal-implants-a-systematic-review\/","title":{"rendered":"Clinical performance of additively manufactured subperiosteal implants: a systematic review"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row content_text_aligment=&#8221;left&#8221; row_background_lines=&#8221;no&#8221;][vc_column][vc_column_text css=&#8221;&#8221;]<\/p>\n<h3 class=\"title\">Abstract<\/h3>\n<div id=\"eng-abstract\" class=\"abstract-content selected\">\n<div id=\"eng-abstract\" class=\"abstract-content selected\">\n<div id=\"eng-abstract\" class=\"abstract-content selected\">\n<p><strong>Purpose:<\/strong> The aim of this study was to assess implant survival and complications rate of modern subperiosteal implants (CAD designed and additively manufactured).<\/p>\n<p><strong class=\"sub-title\">Methods: <\/strong>A systematic review was conducted using three electronic databases; Medline (Pubmed), Cochrane library, and SCOPUS, following the PRISMA statement recommendations to answer the PICO question: &#8220;In patients with bone atrophy (P), do additively manufactured subperiosteal implants (I), compared to subperiosteal implants manufactured following traditional approaches (c), present satisfactory implant survival and complication rates (O)? The study was pre-registered in PROSPERO (CRD42023424211). Included articles quality was assessed using the &#8220;NIH quality assessment tools&#8221;.<\/p>\n<p><strong class=\"sub-title\">Results: <\/strong>Thirteen articles were finally selected (5 cohort studies and 8 case series), including 227 patients (121 female \/ 106 male; weighted mean age 62.4 years) and 227 implants. After a weighted mean follow-up time of 21.4 months, 97.8% of implants were in function (5 failures reported), 58 implants (25.6%) presented partial exposure, 12 patients (5.3%) suffered soft tissue or persistent infection. Fracture of the interim prosthesis was reported in 8 of the155 patients (5.2%) in which the use of a provisional prosthesis was reported. A great heterogeneity was found in terms of study design and methodological aspects. For this reason, a quantitative analysis followed by meta-analysis was not possible.<\/p>\n<p><strong class=\"sub-title\">Conclusions: <\/strong>Within the limitations of this study, modern additively manufactured subperiosteal implants presented a good survival in the short-time, but a noticeable number of soft-tissue related complications were reported. Further studies are needed to assess the clinical behavior in the medium- and long-term.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<p>[\/vc_column_text][vc_empty_space][vc_column_text]<\/p>\n<h3>Figures<\/h3>\n<div id=\"eng-abstract\" class=\"abstract-content selected\">\n<p>[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row][vc_row content_placement=&#8221;middle&#8221; content_text_aligment=&#8221;center&#8221;][vc_column]<div class=\"qodef-image-gallery qodef-grid-list qodef-disable-bottom-space  qodef-ig-grid-type qodef-four-columns qodef-tiny-space  qodef-image-behavior-lightbox\">\n\t<div class=\"qodef-ig-inner qodef-outer-space\">\n\t\t\t\t\t<div class=\"qodef-ig-image qodef-item-space\">\n\t\t\t\t<div class=\"qodef-ig-image-inner\">\n\t\t\t\t\t\t\t\t\t\t\t<a itemprop=\"image\" class=\"qodef-ig-lightbox\" href=\"https:\/\/www.btitrainingcenter.com\/wp-content\/uploads\/2024\/11\/40729_2024_521_Fig1_HTML.jpg\" data-rel=\"prettyPhoto[image_gallery_pretty_photo-340]\" title=\"&lt;strong&gt;Fig. 1.&lt;\/strong&gt; Search strategy flow. Adapted from The PRISMA 2020 statement (Page et al. [38])\">\n\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.btitrainingcenter.com\/wp-content\/uploads\/2024\/11\/40729_2024_521_Fig1_HTML-200x200.jpg\" alt=\"\" width=\"200\" height=\"200\" \/>\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t<\/div>\n\t\t\t<\/div>\n<\/div>[vc_empty_space height=&#8221;50px&#8221;][\/vc_column][\/vc_row][vc_row][vc_column]<a itemprop=\"url\" href=\"\/wp-content\/uploads\/2021\/08\/40729_2024_Article_521-comprimido.pdf\" target=\"_blank\"  class=\"qodef-btn qodef-btn-medium qodef-btn-solid btnWebRosa2\"  >\n    <span class=\"qodef-btn-text\">Artikel herunterladen<\/span>\n    <\/a>[\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<\/div>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p><strong>Int J Implant Dent. 2024 Feb 5;10(1):4 <\/strong><br \/>\nThe aim of this study was to assess implant survival and complications rate of modern subperiosteal implants (CAD designed and additively manufactured).<\/p>\n","protected":false},"author":2002,"featured_media":33753,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[152],"tags":[],"class_list":["post-33759","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-orale-implantologie"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.btitrainingcenter.com\/de\/wp-json\/wp\/v2\/posts\/33759","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.btitrainingcenter.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.btitrainingcenter.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.btitrainingcenter.com\/de\/wp-json\/wp\/v2\/users\/2002"}],"replies":[{"embeddable":true,"href":"https:\/\/www.btitrainingcenter.com\/de\/wp-json\/wp\/v2\/comments?post=33759"}],"version-history":[{"count":2,"href":"https:\/\/www.btitrainingcenter.com\/de\/wp-json\/wp\/v2\/posts\/33759\/revisions"}],"predecessor-version":[{"id":43670,"href":"https:\/\/www.btitrainingcenter.com\/de\/wp-json\/wp\/v2\/posts\/33759\/revisions\/43670"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.btitrainingcenter.com\/de\/wp-json\/wp\/v2\/media\/33753"}],"wp:attachment":[{"href":"https:\/\/www.btitrainingcenter.com\/de\/wp-json\/wp\/v2\/media?parent=33759"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.btitrainingcenter.com\/de\/wp-json\/wp\/v2\/categories?post=33759"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.btitrainingcenter.com\/de\/wp-json\/wp\/v2\/tags?post=33759"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}